7.3.3.5 IfcFlowMeter
| Appareil de mesure de débit |
| Zähler (allgemein) |
A flow meter is a device that is used to measure the flow rate in a system.
HISTORY New entity in IFC4
Plumbing System Design
Instance diagram
Identity
The Identity concept applies to this entity.
Exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
Import |
|
|
|
|
R |
R |
R |
R |
|
|
R |
R |
R |
Export |
|
|
|
|
R |
R |
R |
R |
|
|
R |
R |
R |
Object Typing
The Object Typing concept applies to this entity as shown in Table 82.
|
Table 82 — IfcFlowMeter Object Typing |
Exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
Import |
|
|
|
|
|
|
|
|
|
|
|
|
|
Export |
|
|
|
|
|
|
|
|
|
|
R |
|
R |
Properties for Occurrences
The Properties for Occurrences concept applies to this entity as shown in Table 83.
|
Table 83 — IfcFlowMeter Properties for Occurrences |
Exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
Import |
|
|
|
|
R |
R |
|
|
|
|
|
|
|
Export |
|
|
|
|
R |
R |
|
O |
|
|
O |
O |
O |
Ports
The Ports concept applies to this entity as shown in Table 84.
|
Table 84 — IfcFlowMeter Ports |
Exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
Import |
|
|
|
|
|
R |
|
|
|
|
|
|
|
Export |
|
|
|
|
|
R |
|
R |
|
|
R |
R |
R |
Placement
The Placement concept applies to this entity as shown in Table 85.
|
Table 85 — IfcFlowMeter Placement |
Body Geometry
The Body Geometry concept applies to this entity as shown in Table 86.
|
Table 86 — IfcFlowMeter Body Geometry |
Exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
Import |
|
|
|
|
|
|
|
|
|
|
|
|
|
Export |
|
|
|
|
|
|
|
R |
|
|
R |
R |
R |
Spatial Containment
The Spatial Containment concept applies to this entity as shown in Table 87.
Structure | Description |
IfcSite | Electrical meters are typically placed next to a building on the exterior. |
|
Table 87 — IfcFlowMeter Spatial Containment |
Exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
Import |
|
|
|
|
|
|
|
|
|
|
|
|
|
Export |
|
|
|
|
|
|
|
R |
|
|
R |
R |
R |
XSD Specification:
<xs:element name="IfcFlowMeter" type="ifc:IfcFlowMeter" substitutionGroup="ifc:IfcFlowController" nillable="true"/>
<xs:complexType name="IfcFlowMeter">
<xs:complexContent>
<xs:extension base="ifc:IfcFlowController"/>
</xs:complexContent>
</xs:complexType>
EXPRESS Specification:
|
PredefinedType | : | OPTIONAL IfcStrippedOptional; |
|
|
CorrectPredefinedType | : | NOT(EXISTS(PredefinedType)) OR
(PredefinedType <> IfcFlowMeterTypeEnum.USERDEFINED) OR
((PredefinedType = IfcFlowMeterTypeEnum.USERDEFINED) AND EXISTS (SELF\IfcObject.ObjectType)); | CorrectTypeAssigned | : | (SIZEOF(IsTypedBy) = 0) OR
('IFCHVACDOMAIN.IFCFLOWMETERTYPE' IN TYPEOF(SELF\IfcObject.IsTypedBy[1].RelatingType)); |
|
Formal Propositions:
CorrectPredefinedType | : |
Either the PredefinedType attribute is unset (e.g. because an IfcFlowMeterType is associated), or the inherited attribute ObjectType shall be provided, if the PredefinedType is set to USERDEFINED.
|
CorrectTypeAssigned | : |
Either there is no flow meter type object associated, i.e. the IsTypedBy inverse relationship is not provided, or the associated type object has to be of type IfcFlowMeterType.
|
Inheritance Graph:
|
ObjectType | : | OPTIONAL IfcStrippedOptional; |
|
|
Tag | : | OPTIONAL IfcStrippedOptional; |
|
|
PredefinedType | : | OPTIONAL IfcStrippedOptional; |
|
Link to this page